FiD Gas chromatograph Introduction
The GC112N FID gas chromatograph is a microcomputer based, high-performance, low-priced, and newly designed universal gas chromatograph. It has the advantages of high stability and reliability, simple and reasonable structure, convenient operation, and beautiful appearance. This instrument has a wide range of applications and is suitable for trace detection of pollution in environmental protection, atmosphere, water sources, etc; Analysis, monitoring, and research of toxins; biochemistry; Clinical application; Pathological and viral research; Food fermentation: petrochemical industry; Petroleum processing; Oil analysis; Geological and mineral exploration research; Organic chemistry; Synthesis research; health quarantine; Analysis and research on public hazard detection. The main components of GC112N gas chromatograph
GC112 FID gas chromatograph is equiped with a FID detector.FID is the abbreviation of Flame flame ionization detector which is a high sensitivity universal detector.
It has response to almost all organic substances, but has no response or very little response to inorganic compound substances, inert gases or undivided substances in the flame.
FID gas chromatograph need use pure hydrogen as flame gas.pure nitrogen as carrier gas.you can consider onsite hydrogen generator and nitrogen generator to replace dangerous gas cylinder.
Features of FID gas chromatograph
Features & Specification
Feature:
1.Standard PC side reverse control software
2.Host with 7-inch color touch screen
3.Gas shortage alarm protection function
4.Split flow/split ratio can be automatically controlled to save carrier gas.
5.Configure automatic sampler installation and positioning interface
6.The multi-core, 32-bit embedded hardware system
7.Using logarithmic amplifier, detection signal no cut-off value, good peak shape, extensible synchronous external trigger function
8.One-button start function
9.It has perfect system self-check function and fault automatic identification function.
10.With 8 external event extension function interface
11.RS232 communication port and LAM network port
Technical Specifications:
Column temperature box | |
Content product | 22L |
Temperature control range | 5ºC ~ 400ºC at room temperature |
Temperature control accuracy | ±0.1ºC |
Heating rate | 0.1 ~ 60ºC / min |
Program temperature rise order | 9 |
Program heating repeatability | ≤ 2% |
Cooling way | open the door after |
Cooling speed | ≤10 mins (250ºC ~ 50ºC) |
Control software function | (GC112N only) |
Column temperature box control | Detector controlInjector controlMap display |
Sampler | |
Temperature control range | 7ºC ~ 420ºC at room temperature |
Temperature control method | independent temperature control |
Carrier gas flow control mode | constant pressure |
Number of simultaneous installations | 3 at most |
Type of injection unit | filling column, shunt |
Split ratio | split ratio display |
Cylinder pressure range | 0 ~ 400kPa |
Cylinder pressure control accuracy | 0.1kPa |
Flow setting range | H2 0 ~ 200ml / minN2 0 ~ 150ml / min |
Detector | |
FID, TCD optional | |
Temperature control | Max. 420ºC |
Number of simultaneous installations | 2 at most |
Ignition function | automatic |
Hydrogen flame ionization detector (FID) | |
Detection limit | ≤ 3×10 g/s (n-hexadecane) |
Baseline noise | ≤ 5× 10-14A |
Baseline drift | ≤ 6× 10-13A |
Dynamic range | 107 |
RSD | 3% or less |
Thermal conductivity detector (TCD) | |
Sensitivity | 5000mV•mL/mg (n-cetane) |
Baseline noise | ≤ 0.05 mV |
Baseline drift | ≤ 0.15mV / 30min |
Dynamic range | 105 |
Supply voltage | AC220V±22V, 50Hz±0.5Hz |
Power | 3000W |
FID gas chromatograph need pure hydrogen as flame gas.below is the link of PEM pure hydrogen generator.
FID gas chromatograph also need dry compressed air as or zero air as Auxiliary combustion gas.below is the related link